Aoda M310T Portable digital touch screen Multiparameter water analyzer


057a18bc-bbc8-411e-98c4-73d1a5bc2df1.pngGENERAL FEATURES

  • Color High contrast LCD touchscreen, 4.3 inches.

  • Multi-reading feature allows auto-read, timed-read and continuous-read. 

  • Automatic/Manual temperature compensation ensures accurate results.

  • Auto-hold feature senses and locks the measurement endpoint.

  • Data capacity of up to 500 sets for each parameter (GLP-compliant).

  • Support for USB communication.

  • Auto-power off feature effectively extends the battery service life.

  • Reset feature automatically resumes all settings back to factory default options.

  • IP65 waterproof. The portable meter is suitable for fields measurements and out door measurements.


pH

1-5 points calibration with Standard Recognition.

Selectable pH buffer groups, including NIST, DIN, GB.

Automatic electrode diagnosis with pH slope and offset display.


Ion

  • 1-5 points calibration.

  • Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, ppm, etc.

  • Measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode.

  • Over 10 methods are built-in, including F-, Cl-, Br-, I-, NO3-, BF4-, NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Ag+ and etc., user-defined method is supported.


Conductivity

  • 1-3 points calibration with Standard Recognition.

  • Settable parameters, including cell constant, temperature compensation coefficient, and TDS factor.

  • Temperature compensation type (none, linear, pure water).


DO

  • Support for air-saturated water or zero oxygen calibration.

  • Auto barometric pressure compensation

  • Manual Salinity Factor Correction

  • Selectable pressure unit, including kPa, mbar, Torr, Atm.


057a18bc-bbc8-411e-98c4-73d1a5bc2df1.pngSpecifications

Model

M310T Multiparameter water analyzer

Parameters

pH/EC/ISE/DO/Temp. (mV/pX/Resistivity/TDS/Sal./DO Saturation)

pH

Range

-2.00 to 20.00 pH

Resolution

0.1, 0.01 pH

Accuracy

±0.01 pH

Calibration Points

Up to 5

Standard Customization

Yes

Calibration Reminder

Yes

Standard Recognition

NIST, GB, USA and DIN buffers

Slope Limit

Yes

mV

Range

-2000.0 to 2000.0 mV

Resolution

0.1 mV

Accuracy

±0.3 mV or ±0.1%

pX

Range

-2.00 to 20.00 pX

Resolution

0.1, 0.01 pX

Accuracy

±0.01 pX

Calibration Points

Up to 5

ISE

Range

1.000e-9 to 9.999e+9

Units

mol/L, mmol/L, g/L, mg/L, μg/Lppm, ppb

Resolution

Up to 4 significant digits

Accuracy

±0.5%

Calibration Points

Up to 5

Conductivity

Range

0.000 μS/cm to 1000 mS/cm

Resolution

0.001 μS/cm minimum,

various with range selection

Accuracy

±1.0% FS

Reference Temperature

20, 25 ºC

Calibration Points

Up to 3

Standard Recognition

84μS/cm, 1413μS/cm, 12.88mS/cm

Resistivity

Range

5.00 Ω·cm~20.00 MΩ·cm

Resolution

0.01Ω ·cm minimum,

Accuracy

±1.0% FS

TDS

Range

0.00 ppm~300 ppt

Resolution

0.01mg/L minimum, 3 significant digits

Accuracy

±1.0%FS

Salinity

Range

0.0~80.0 ppt

Resolution

0.1ppt

Accuracy

±2ppt

Dissolved

Oxygen Concentration

Sensor Type

Polarographic

Range

0.00 to 50.00 ppm

Resolution

0.01mg/L 

Accuracy

±0.10ppm

Calibration Points

Air-saturated water or zero point

Barometric Compensation

Yes

Manual Salinity Factor Correction

Yes

Saturation

Range

(0.0 to 300.0)%

Resolution

0.10%

Accuracy

±2.0%

Temperature

Range

-5 to 110 ºC, 23.0 to 230 ºF

Unit

ºC, ºF

Resolution

0.1

Accuracy

±0.2ºC

Measurement

Reading Mode

Auto-Read (Fast, Medium, Slow), Timed, Continuous

Reading Prompts

Reading, Stable, Locked

Temp. Compensation

ATC, MTC

Data management

Data Storage

1000 Groups

GLP Features

Yes

Inputs

pH Electrode

BNC(Q9)

DO with Temp. Probe

4-pin aviation connector

Conductivity with Temp. Probe

5-pin aviation connector

Outputs

USB

PC, printer

Display options

Backlight

Yes

Auto Shutdown

300, 600, 1200, 1800, 3600sec., off

IP Rating

IP65

Date and Time

Yes

General

Power

Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output

Dimensions

90 x 255 x 40 mm

Weight

500g (1.1 lb)

Dimensions (Carton)

4941220 mm

Weight (Gross)

5.5 kg

057a18bc-bbc8-411e-98c4-73d1a5bc2df1.png Images

M310T.jpg

Wristbands for easy carryingBNC/4-pin/5pin connectorsUSB interface for charging and data uplaoding
300x300 详情图.jpg300x300 详情图2.jpg300x300详情图3.jpg

057a18bc-bbc8-411e-98c4-73d1a5bc2df1.pngFAQ

Q : What is the use of Multiparameter water quality meter?

A : Multiparameter water analyzer can measure a number of water quality parameters, including pH, conductivity,EC,TDS,Salinity,Dissolved oxygen,Ion,Temperature.

 

Q : How parameters it can test a time ?

A : 3 parameters can be tested at a time.


Q : What buffer included ?

A : NIST pH standard solution(4.01, 7.00, 10.01)  and 1413μS/cm EC standard solution included.


Q : What ions it tests ?

A : F-, Cl-, Br-, I-, NO3-, BF4-, NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Ag+ ions and etc can be tested.