Aoda T960 high-precision laboratory experimental analysis Automatic Potentiometric Titrator
T960 Automatic Potentiometric Titrator is a high-precision laboratory experimental analysis instrument that uses potentiometric, dead-stop, other titration methods for capacity analysis. ...
- Fast Delievery
- Quality Assurance
- 24/7 Customer Service
Aoda T960 high-precision laboratory experimental analysis Automatic Potentiometric Titrator
T960 Automatic titrator is a high-precision laboratory experimental analysis instrument that uses
potentiometric, dead-stop, other titration methods for capacity analysis. It can perform acid-base titration,
redox, precipitation, complexation, dead-stop, etc. It has the functions of constant titration, micro titration,
end point setting titration, volume setting titration and mode titration, etc. At the same time, it can choose
or build its own special titration mode according to the actual needs of users.
T960 series of products can be used in food, drug inspection, disease control, inspection, commodity
inspection, water treatment, petroleum, chemical, marine, electric power, environmental protection, new
energy, teaching, scientific research, and other fields.
Features
*Multi-channel modular combination, which can combine multiple dosing units; supports 4 dosing units
to work at the same time, free combination, no need to install and disassemble parts, and each module
can be simply side-by-side to form an instrument system
*4 types of standard burettes for adding liquid can be selected arbitrarily, and the experimental application
is more targeted; standard 10mL, optional 1mL, 5mL, 25mL
*Built-in dosing unit, multiple guarantees against the danger of reagent spillage; minimize the risk of
operators
*Multiple self-check functions, simplify the operation process and avoid misoperation
*With the application editing function, the user can generate a special titration mode according to the
experiment and store it, and the next one-click retrieval
*With the audit trail function, the effective operation of the instrument will be recorded in the background
and cannot be deleted
*Have user hierarchical authority management, and can check the specific use authority when creating an
account
*With the function of password aging, each account can set the validity period of the password. After the
expiration, it is mandatory to change the password before logging in to the instrument.
*With password complexity setting, you can set the password complexity according to your needs
*Support the manual setting of endpoints and save as associated data to reduce unnecessarily repeated
experiments
Hybrid Synchronized Liquid Feeding System
Up to 4 channels, any combination of titrants, additives or auxiliary reagents frees the complicated liquid
feeding requirements from manual operations.
Built-in Burette
Built-in burette, the burette is built into the instrument, and the burette can be observed externally through
the window, so that the solution is separated from the personnel during the running process and avoids
spillage and damage to the operator. Volumetric burette optional: 1mL/5mL/10mL/25mL.
Multiple Measurement Modes
MEAS: measure pH/mV/T, CAL: pH calibration, SET setting end point mode, MET equivalent titration,
MET equivalent titration second-order derivative method (chlorine ion measurement), DET dynamic titration,
constant pH titration, manual titration, etc.
Multiple Titration Modes
Acid-base titration, redox titration, silver volume titration, complexometric titration, dead-stop titration.
Wireless Wi-Fi Module
T9605 wireless Wi-Fi module, the wireless connection between the computer and the titrator, remote control
of the instrument, reducing the time when the experimenter is in close contact with chemical reagents.
Specifications
Specifications of T960 Automatic Titrator | ||
T960 Basic | T960 Pro | |
Titration module | Potentiometric | Potentiometric, Dead-stop |
mV Measuring range: | -2000.0mV~+2000.0mV | ● |
mV Measuring: | Resolution: 0.1mV, Accuracy: 0.1mV±0.03% | ● |
pH Measuring range: | -20.000pH~+20.000pH | ● |
pH Measuring: | Resolution: 0.001pH Accuracy: 0.003pH | ● |
Temp.Measuring range: | -5~120℃ | ● |
Temp. Accuracy: | ±0.1℃ | ● |
Maximum number of titration modules | 4 (2 modules in the standard package) | ● |
Maximum number of simultaneous filling modules: | 4 (2 modules in the standard package) | ● |
Burette optional | 1mL 5mL 10mL 25mL(10ml burette in the standard package ) | ● |
Burette resolution | 1/1500000 | ● |
Burette refill time: | 16 seconds (100% filling speed) | ● |
User grading management system | 3 level (Customizable operation permissions) | ● |
Audit trail | ○ | ● |
Controlled by | PC | ● |
WiFi module | ○ | ● |
Stirring | Magnetic stirring, upper stirring (optional) | ● |
Electrode interface type: | mV/pH measuring electrode interface, reference electrode interface, | mV/pH measuring electrode interface, reference electrode interface, |
PT1000 temperature electrode interface | PT1000 temperature electrode interface, polarized electrode interface | |
Autosampler (Optional) | Equipped with 1 independent analysis station, optional 16-position 100mL autosampler, 12-position 250mL autosampler, and 18-position 50mL autosampler |
Product photo