Aoda WG Series Fully Automatic Horizontal Pulse Vacuum Autoclave
WG series pulsating vacuum sterilizers are mainly used in disinfecting supply rooms of hospitals, third-party disinfecting supply centers, and operating rooms, where medical devices, dressings, rubber, lumen devices, implantable devices, and liquids are s...
- Fast Delievery
- Quality Assurance
- 24/7 Customer Service
Aoda WG Series Fully Automatic Horizontal Pulse Vacuum Autoclave
WG series pulsating vacuum sterilizers use saturated steam as the sterilizing medium, and relying on the physical property that saturated steam can release a large amount of latent heat and moisture during condensation, it renders items to be sterilized in a highly heated and humid state. After a period of heat preservation, purpose of sterilization is achieved. The effect of cold air on temperature is eliminated by means of pulsating vacuum exhaust, and finally vacuum dehumidiffication is realized in a jacket device to dry the sterilized items.
WG series pulsating vacuum sterilizers are mainly used in disinfecting supply rooms of hospitals, third-party disinfecting supply centers, and operating rooms, where medical devices, dressings, rubber, lumen devices, implantable devices, and liquids are sterilized.
Pulse Vacuum Autoclave Characteristics
It is designcd and manufactured in accordance with GB150 the Pressure Vessel. GB8599 The Technieal Requirements of Large Steam Serilier-Automatic Control Protocol and TSG Rt004 the -Safety and Technology Specifieation for Fixcd Monitor VesseNi and related insetion procedures.
The chamber in horizontat rectangular shape with doublelayer structure is made from S3008.
Doot sealing: Pneumatic scaling: both doors are interlocked and completely conform to the requirements of the specification
With standard GMP authentication interface.
Strlizer piping sysem: the pipeline is designed with the best configuration.
Sterilizer control system: SIEMENS PLC and SIEMENS touch screen, this system is easy to implement the program selection, parameter seting equipment opeation, report processing and other functions. It has prfect safety measures The FO value and the temperature time gives doublc guarantee for selizaion A single parameter control is also available. It has a prfect sterilization records.
Pulse Vacuum Autoclave Main Parameters and Utilities
Design Pressure | 0.245Mpa | Working Pressure | 0.225Mpa |
Design Temperature | 139℃ | Working Temperature | 105-134℃ |
Vacuum | -0.09Mpa | Temperature Equilibrium | ≤±1℃ |
Water Source Pressure | 0.15-0.3Mpa | Compressed Air Pressure | 0.3-0.7Mpa |
Steam Pressure | 0.3-0.7Mpa | Power | AC380V, 50HZ |
Pulse Vacuum Autoclave parameter details
Model | Overall Size L×W×H(mm) | Chamber Size L×W×H(mm) | Steam Consumption(KG) | Tap Water Consumption(KG) | Power(KW) | Net Weight(KG) |
WG-0.1 | 950×1200×1750 | 560×400×450 | 14KG | 25KG | 2+12KW | 700KG |
WG-0.15 | 1050×1200×1750 | 750×400×450 | 14KG | 25KG | 2+12KW | 800KG |
WG-0.2 | 1120×1305×1840 | 1000×450×450 | 16KG | 30KG | 2+24KW | 850KG |
WG-0.25 | 1100×1350×1900 | 800×600×600 | 18KG | 35KG | 2+24KW | 900KG |
WG-0.36 | 1300×1350×1900 | 1000×600×600 | 25KG | 40KG | 2+24KW | 1000KG |
WG-0.6 | 1500×1360×1950 | 1200×610×910 | 30KG | 45KG | 3+36KW | 1400KG |
WG-0.8 | 1800×1360×1950 | 1500×610×910 | 40KG | 50KG | 3KW | 1600KG |
WG-1.2 | 1750×1440×1950 | 1450×680×1180 | 48KG | 55KG | 4KW | 1800KG |
WG-1.5 | 2150×1440×1950 | 1850×680×1180 | 55KG | 60KG | 4KW | 2000KG |
WG-2.0 | 1950×1750×2200 | 1600×900×1400 | 65KG | 65KG | 4.5KW | 2500KG |
WG-2.5 | 2300×1750×2200 | 1950×900×1400 | 75KG | 75KG | 6KW | 3000KG |
WG-3.0 | 2700×1750×2200 | 2400×900×1400 | 90KG | 90KG | 8KW | 3500KG |
Pulse Vacuum Autoclave photo
Autoclave Workshop
CONTACT NOW