Aoda WG Series Fully Automatic Horizontal Pulse Vacuum Autoclave

Aoda WG Series Fully Automatic Horizontal Pulse Vacuum Autoclave

WG series pulsating vacuum sterilizers are mainly used in disinfecting supply rooms of hospitals, third-party disinfecting supply centers, and operating rooms, where medical devices, dressings, rubber, lumen devices, implantable devices, and liquids are s...

  • Fast Delievery
  • Quality Assurance
  • 24/7 Customer Service

Aoda WG Series Fully Automatic Horizontal Pulse Vacuum Autoclave

WG series pulsating vacuum sterilizers use saturated steam as the sterilizing medium, and relying on the physical property that saturated steam can release a large amount of latent heat and moisture during condensation, it renders items to be sterilized in a highly heated and humid state. After a period of heat preservation, purpose of sterilization is achieved. The effect of cold air on temperature is eliminated by means of pulsating vacuum exhaust, and finally vacuum dehumidiffication is realized in a jacket device to dry the sterilized items.


WG series pulsating vacuum sterilizers are mainly used in disinfecting supply rooms of hospitals, third-party disinfecting supply centers, and operating rooms, where medical devices, dressings, rubber, lumen devices, implantable devices, and liquids are sterilized.


Pulse Vacuum Autoclave Characteristics

  • It is designcd and manufactured in accordance with GB150 the Pressure Vessel. GB8599 The Technieal Requirements of Large Steam Serilier-Automatic Control Protocol and TSG Rt004 the -Safety and Technology Specifieation for Fixcd Monitor VesseNi and related insetion procedures.

  • The chamber in horizontat rectangular shape with doublelayer structure is made from S3008.

  • Doot sealing: Pneumatic scaling: both doors are interlocked and completely conform to the requirements of the specification

  • With standard GMP authentication interface.

  • Strlizer piping sysem: the pipeline is designed with the best configuration.

  • Sterilizer control system: SIEMENS PLC and SIEMENS touch screen, this system is easy to implement the program selection, parameter seting equipment opeation, report processing and other functions. It has prfect safety measures The FO value and the temperature time gives doublc guarantee for selizaion A single parameter control is also available. It has a prfect sterilization records.


Pulse Vacuum Autoclave Main Parameters and Utilities

Design Pressure

0.245Mpa

Working Pressure

0.225Mpa

Design Temperature

139℃

Working Temperature

105-134℃

Vacuum

-0.09Mpa

Temperature Equilibrium

≤±1℃

Water Source Pressure

0.15-0.3Mpa

Compressed Air Pressure

0.3-0.7Mpa

Steam Pressure

0.3-0.7Mpa

Power

AC380V, 50HZ
The three-phase and five-wire system AC380V,50HZ


Pulse Vacuum Autoclave parameter details

Model

Overall Size L×W×H(mm)

Chamber Size L×W×H(mm)

Steam Consumption(KG)

Tap Water Consumption(KG)

Power(KW)

Net Weight(KG)

WG-0.1

950×1200×1750

560×400×450

14KG

25KG

2+12KW

700KG

WG-0.15

1050×1200×1750

750×400×450

14KG

25KG

2+12KW

800KG

WG-0.2

1120×1305×1840

1000×450×450

16KG

30KG

2+24KW

850KG

WG-0.25

1100×1350×1900

800×600×600

18KG

35KG

2+24KW

900KG

WG-0.36

1300×1350×1900

1000×600×600

25KG

40KG

2+24KW

1000KG

WG-0.6

1500×1360×1950

1200×610×910

30KG

45KG

3+36KW

1400KG

WG-0.8

1800×1360×1950

1500×610×910

40KG

50KG

3KW

1600KG

WG-1.2

1750×1440×1950

1450×680×1180

48KG

55KG

4KW

1800KG

WG-1.5

2150×1440×1950

1850×680×1180

55KG

60KG

4KW

2000KG

WG-2.0

1950×1750×2200

1600×900×1400

65KG

65KG

4.5KW

2500KG

WG-2.5

2300×1750×2200

1950×900×1400

75KG

75KG

6KW

3000KG

WG-3.0

2700×1750×2200

2400×900×1400

90KG

90KG

8KW

3500KG