Aoda XRY-1A petroleum products coal calorific value test Oxygen Bomb Calorimeter
XRY-1A Oxygen Bomb Calorimeter is suitable to determine calorific value of combustible materials such as petroleum products without water (gasoline, jet fuels, diesel oil and fuel oils, etc.), coal, coke and paraffin, etc....
- Fast Delievery
- Quality Assurance
- 24/7 Customer Service
Aoda XRY-1A petroleum products coal calorific value test Oxygen Bomb Calorimeter
The Oxygem Bomb Calorimeter is designed and made as per the National Standard of People’s Republic of China GB/T213-2008 and ASTM D240 Test Method for Calorific Value of coal, GB/T384-1988 Test Method for Calorific Value of Petroleum Products and Calibration Regulation of People’s Republic of China JJG672-2001 Oxygen Bomb Calorimeter, as well as Enterprise Standard of Shanghai Q/YXYY 10 XRY Series Oxygen Bomb Calorimeter.
The heat capacity of the instrument is 14000 J/K~15000 J/K.
XRY-1A Oxygem Bomb Calorimeter is suitable to determine calorific value of combustible materials such as petroleum products without water (gasoline, jet fuels, diesel oil and fuel oils, etc.), coal, coke and paraffin, etc.
1. This XRY-1A Oxygen Bomb Calorimeter adopts sealed oxygen bomb. The whole structure adopts stainless steel material. The strength is enough to resist the max pressure (60~70 atmospheric pressure) when the solid burning. And it can resist the bigger pressure when liquid fuel burning.
2. The inner water cylinder is composed of stainless steel sheet.The cross section is pyriform and the capacity is 3kg. The water cylinder is equipped with electric stirrer inside. It ensures the temperature in the water cylinder uniform.
3. The external water jacket is double layer container. It filled with water when doing determination.It make the water temperature in the cylinder uniform by water jacket stirrer and form the constant temperature environment meeting the requirements of test.
XRY-1A Oxygen Bomb Calorimeter | |
Power supply | AC (220V±10%), 50 Hz |
Total power consumption | ≤150W |
Heat capacity | 14400 J/K~14500 J/K |
Resolution | 0.001 K |
Measurement accuracy | ≤ 60J/g |
Temperature measurement range | 10 ℃~35 ℃ |
Repeatability | ≤0.2% (Grade C) |
Pressure endurance of oxygen bomb | 20 MPa |
Ambient temperature | (15~28) ℃, the fluctuation is not more than 1 ℃ during one test |
Data saved | 31 pieces |
Relative humidity | ≤85% |
Dimensions | 600mm×460mm×430mm |
Note: Pellet press machine is optional accessory if sample is powder.